<< Previous Message Main Index Next Message >>
<< Previous Message in Thread This Month Next Message in Thread >>
Date   : Tue, 16 Sep 2003 15:06:55 +0100
From   : Nick B <nickbeee@...>
Subject: Re: Mark de Weger's XFER

BBC Micro wrote:
>  --- Bob Devries <bdevries@...> wrote: > I
> tried to use Mark's XFER V3.0, but I get runtime

>>error 200 at 0000:0986
>>(for 1STXFER), and runtime error 200 at 0000:0155
>>for XFER.
Thats the classic Borland/Turbo Pascal error that you see when running 
progs compiled with BP/TP on machines faster than about 500MHz. It was 
due to a bug in the BP/TP CRT unit. This could be fixed if anyone has 
the Pascal source for Xfer 3 as there is a replacement CRT unit available.
As suggested the best fix now is to get XFER4 which is written in C and 
compiled for 32-bit executables.
<< Previous Message Main Index Next Message >>
<< Previous Message in Thread This Month Next Message in Thread >>