Date : Fri, 29 Jul 2005 21:11:22 +0200
From : "Mark Usher" <mu.list@...>
Subject: FW: Re: Econet-Ethernet bridge
Grrrrr. Replied privately, here it is to the list....
>Econet Data Link and Physical Layer Specification is 30 pages, version
>3.0 provisional, August '82.
I've got at least part of this (I think) OCR'ed. Only 11 pages though and is
entitled Econet Data Transfer. Starts of as below.
Mark
ECONET LAYERING
The International Standards Organisation (ISO) have defined a seven layered
model of network communication in an attempt to set an international
standard:
LOCAL STATION REMOTE STATION
7 Application Application
| |
6 Presentation Presentation
| |
5 Session Session
| |
4 Transport Transport
| |
3 Network Network
| |
2 Data link Data link
| |
1 ------------- Physical------------------
Since in an ECONET system Acorn Computers Ltd are responsible for all bar
the Application level, it was appropriate to combine ISO layers in the
ECONET design, such that it is a three-layered network with each layer
system-independent of the others: