Date : Mon, 13 Aug 2007 08:11:33 +0100
From : pete@... (Pete Turnbull)
Subject: Emulating Econet hardware?
On 13/08/2007 05:03, Jonathan Graham Harston wrote:
> "There are two Z80-SIO options: the Z80-SIO/0 and the Z80-SIO/1...
> see figure C4-3
>
> Figure C4-3:
>
> 28 +<--RxDB
> 27 +<--RxCB 27 +<-- RxTxCB
> 26 +<--TxCB 26 +--> TxDB
> 25 +-->TxDB 25 +--> DTRB
> 24 +-->RTSB \ \
> \ \
> Z80-SIO/0 Z80-SIO/1 "
>
> pC4-22, Zilog Device Datasheets, Adam Osbourne & Associates.
Then that's a misprint, and probably a very early copy of a datasheet if
it only admits to two versions. I have several Zilog datasheets, and
the SGS data book, and they all disagree with what you wrote, and agree
with what I wrote. There are plenty of references on the internet too,
if you look. Besides, I've actually used Zilog SIO/2s (and SIO/0s). I
have a lump of conductive foam with 6 genuine Zilog ones in front of me
right now :-)
--
Pete Peter Turnbull
Network Manager
University of York