<< Previous Message Main Index Next Message >>
<< Previous Message in Thread This Month Next Message in Thread >>
Date   : Tue, 12 May 2009 08:48:47 +0100
From   : joel@... (Joel Rowbottom)
Subject: BBC B+ Econet weirdness

On Mon, 11 May 2009 19:57:30 +0100, Michael Firth <mfirth@...>
wrote:

> When the machine is powered on, there is about a 50% chance that it 
> won't communicate on the Econet. Any Econet commands will just hang 
> indefinitely.

Probably not helpful, but we saw exactly these symptoms on an odd Master
128 at the Byte Back show. Replacing the Econet module seemed to fix it,
ISTR (although Ian will probably remember better).
<< Previous Message Main Index Next Message >>
<< Previous Message in Thread This Month Next Message in Thread >>