<< Previous Message Main Index Next Message >>
<< Previous Message in Thread This Month Next Message in Thread >>
Date   : Tue, 25 Dec 1984 22:31:00-EST
From   : "Robert L. Plouffe" <PLOUFF@mit-mc.ARPA>
Subject: Patches for MODM700

There is now a patch file at SIMTEL20 in the CPM.MODEM7 archive
that allows patching of MODM700 for the following features:

       1.      Allow rubout to go to console and optionally
       eliminate the control character feature.

       2.      The UNDO-J option that restores terminal mode
       as the default at the calling end and command mode at
       the called end after completion of file transfers.  Yhis
       is how Ward originally wrote it and the preferred mode
       by many.

       3.      Corrected error that caused the wrong file to be
       erased (in some instances) when overwiting files in
       batch mode.  This patch was in PAT730Vx.ASM but did not
       make it into MODM700.

       4.      Allows for optional MAXWAIT times in the protocol
       to improve operation when operating with satellite
       communication links or with packet switched networks
       that can sometimes throttle and give excessive and
       variable packet delays.
<< Previous Message Main Index Next Message >>