Subject: MAXRom and TEAC FD55 drive 1.2M??
In article <1990Oct10.050507.452@simasd.uucp>, donm@pnet07.cts.com (Don
Maslin) writes:
> In view of the obviously broad interest, please post it to the net! Thanks.
> - don
>
> UUCP: {nosc ucsd crash ncr-sd}!pnet07!donm
> ARPA: simasd!pnet07!donm@nosc.mil
> INET: donm@pnet07.cts.com
The problem is it is Hard Copy! It's got alot of timing diagrams and related
graphics material. Fine print as well, so I'll just give a quick strapping
review here now:
TEAC FD-55GFR
default strapping: D1, DC, FG
Adjustable: D0-D3, Addressing
U0-U1, LED indicator control
(Use with IU; In Use signal)
ML Spindle motor On/Off control
(Off state: MOTOR ON * disk
On State : [MOTOR ON + LED] * disk)
IU Will expect IN USE signal on pin 4
of 34 pin interface if jumpered.
RY/DC Selects function of pin 34 signal from
drive: either READY or DISK CHANGE
Operation mode straps:
LG On state is pin 2 LOW = High density
Off state is pin2 LOW = Normal density
(Pin 2 signal is HIGH/NORMAL DENSITY)
E2 Selects output condition of INDEX and
READ DATA pulses. (Complex waveforms)
I & IS I On state: dual speed mode 300/360 RPM
(Controlled by pin 2)
I & IS both Off state: 360 RPM always
I & IS both On: Dual speed with
maintenance of READY signal
during High/Normal change.
Sorry I skipped over U strapping a bit as well as E2, but you get the idea I
hope! This would have gotten me going when I had a 55GFR. . .
Happy strapping!!! 8-)