Date : Sun, 21 Apr 1991 23:25:04 GMT
From : baron!baron!pnet07!donm@nosc.mil (Don Maslin)
Subject: Re: Help: Tandon Disk Drive & Xebek controller
etpkg@levels.sait.edu.au writes:
>So, If someone has details of the jumpers of the Tandon drive they would be
>much appreciated....
The jumpers and factory settings for the TM 50x drives are as below:
Jumper Function Setting Usage
W1 Track Fault O Install for excess track fault
W2 Test O Install for factory test
W3 Disable Limit O Install to disable soft limits
W4 Spin Select O Install for spin select
W5 Tracks S Install for standard version
W6 Motor Type - Install for Type 1.8 motor
RTW7 Read Terminator I Close only at end drive of
daisy chain data. Closed for
radial data.
WTW8 Write Terminator I
S4W9 Drive Select 4 O Install one of four plugs only
S3W10 Drive Select 3 O Plug corresponds to drive addr
S2W11 Drive Select 2 O
S1W12 Drive Select 1 I
3PW13 Three Disk 503 Close for TM503 only
U22 Terminator Pack I Install in end drive of daisy
chain.
NOTES:
O Omit
I Install
S Close jumper for standard version only
503 Close jumper for TM503 only
> [...] The hard disk controller in the ICL is a Xebek Systems
>model 104526 (at least thats the only number written on it). The jumper
>settings for this would also be good.
>
Sorry, I can't help you out on that. Perhaps someone else will.
- don
Keeper of the CP/M System Disk | UUCP: {nosc ucsd crash ncr-sd}!pnet07!donm
Archives for the Dino(saur)SIG | ARPA: simasd!pnet07!donm@nosc.mil
- San Diego Computer Society - | INET: donm@pnet07.cts.com